(1) Once the support page opens please select the country in which you're located. HP Technical Support can be reached by clicking on the following link: You may do so either by Contacting HP (free of charge if under factory warranty) or by obtaining the universal part number using the HP Parts Surfer and ordering the part on the HP Parts Store.Īlternatively, you may use the universal part number to purchase battery at the local retailer as well. So 60Ah.I appreciate you going through the test results and Yes, you may replace the battery to fix the issue, If you now have a utilization ratio of, for example, 50% in one shift (8 working hours).
/cdn.vox-cdn.com/uploads/chorus_image/image/69621476/DSC02727_dbohn_verge.0.jpg)
The power loss of the DC / AC converter is not taken into account in this case. That means that this 369VA must also be supplied on the 24V DC side.ĭC side: Power supply: 369 W / 24V = approx. To put it simply, the power that is taken from the DC / AC converter must also be supplied.ĪC side: Current consumption: 369VA / 30V = approx.

In normal operation, the total power consumption is, for example, 1.230W * 30% = 369W. Please check the data sheet for this.ĬAUTION: Does not correspond to the specifications for standby mode. In normal operation we assume that the workstations have about 30% power consumption during operation. normal operation, is therefore very important. The question of the average power consumption, i.e. The maximum power has already been calculated. As a basis, a mix ratio between usage time and standby time of the consumers is to be found. It's more about how long my battery will last. To get security, the 1800 W would be an alternative. The exact power consumption of the TSC printer is not definitely clear, the 1200W converter appears to be at its limits. The peak at the moment of switch-on must be intercepted by the DC / AC converter. The important thing is that there is room for improvement. The selection of the DC / AC converter is derived from this.
The battery plus#
The customer now tells us, for example, that the TSC printer is being used and that the following combinations are possible, plus all other consumers such as PC, etc. In particular, the power consumption of the printer must be carefully observed here, and the behavior is similar during printing Here all systems start up and start up at the same time. The start-up of all components at switch-on time. An upward tolerance should therefore always be taken into account.ġ.1.
The battery manuals#
Note: The data sheets and manuals often provide relatively nimble information on the maximum values of the devices. Scanner - supply voltage 5V DC / power consumption approx.
The battery Pc#
PROFI PANEL PC - supply voltage 24V DC / approx. HP Laserjet P3015 - supply voltage 230V AC / worst case power consumption 750 W, standby operation 10W 220 W, no information on current consumption TSC TTP2410MT - supply voltage 230V AC / power consumption approx. ZEBRA ZM400 - supply voltage 230V AC / current consumption 5A at 230V AC approx. Supply voltage Information on consumption in terms of current consumption or powerĪ distinction must be made between print mode or start-up and standby To design the battery technology, we have to consider the following two scenarios: start-up and continuous operation Determination of supply and consumptionīased on the manufacturer's technical documentation (data sheet, etc.), the first task is to determine the supply voltage and power consumption of the devices. 2x ZEBRA ZM400, TSC TTP2410MT, HP Laserjet P3015ġ. The following printer components should be used on the mobile workstation: FORSIS PANEL PC PROFI S 2150 MT with scanner and various printers: e.g. We assume that the customer wants to configure a large and flexible system and therefore has a large number of end devices Using a specific example, we want to work out the dimensioning of a battery supply for a mobile workstation together. The advantages can be seen clearly above.

The battery full#